Home

Site Map    FAQ


Full Brochure List
Distribution Amplifiers
Field Strength Meters
Frequency Counters
Frequency Dividers
Frequency Standards
Function Generator
GPS Amplifier/Splitter
GSM Products
Misc. Products
Multimeter 6.5 digit
Oscillators
Phase Noise Testing
Power Amplifiers
Power Supplies
Protek Products
Redundant Systems
Rubidium Oscillators
Signal Generators
Spectrum Analyzers
Timing Systems
UMTS / GSM Tester
 

Protek Universal Frequency Counter

 
   
 

Features:

  • Measurable up to 3 GHz Frequency Range
  • Two Inputs
  • Variable Measurement & Auto Check (Self Test) Function
  • Large Sized 8 digit LCD display with 20 X 2 Lines
  • Convenient Analyze with GPIB Module.(option)
Frequency Range 0.01Hz ~ 3GHz
Measurement Function Frequency, Period, Time Internal, Ratio A/B Totalized, Self - Test Function
Period Measurement Range 10ns ~ 100s
Time Interval 200ns ~ 1000s
Input Voltage 10MHz 30mVrms ~ 1.5Vrms
10MHz ~ 100MHz 50mVrms ~ 1.5Vrms
100MHz ~ 3GHz 30mVrms ~ 1Vrms
Accuracy ±1 X 10-7/Gate
Input Coupling CH A : AC/DC CH B : AC
Input Impedance 1MΩ 45pF/ 50Ω
Trigger Level -2.5V ~ +2.5V
Operating Voltage 110 / 220V ± 10%/ 40VAmax
Dimension/ Weight 320(D) X 350(W) ´ 88(H)mm / 7kg

The Protek U2000A is a low cost universal time interval and frequency counter.

It has the following functions:

  • Two inputs.  The sensitivity is typically better than 50 mV rms.  The input impedance can be selected as either 1 M ohm or 50 ohm.
  • Frequency:  Measure the frequency in the range 0 to 3 GHz.
  • Period:  Measure the period of a signal.  This is useful for low frequency, since it is quicker and easier to measure the period of a low frequency signal.  Then the frequency can be calculated by taking the inverse of the measurement.
  • Time Interval:  This is where there are two signal inputs.  The U2000A will measure the time difference between the two signals.  The rising edge or falling edge can be used to make these measurements.  Time differences from 200 ns to 1000 seconds can be measured.
  • Ratio:  Again there are two frequency inputs.  The ratio of A/B will be calculated. 
  • Totalize:  Here there is one input and the U2000A will just count as long as there is a signal there.  When the signal is removed, the counting will stop.

The accuracy of any measurement is related to the accuracy of the reference oscillator or timebase.  The U2000A's reference oscillator has an ageing rate of 0.3 ppm and a temperature coefficient of 0.5 ppm over the 0 to 30 degree range.

Other Frequency Counters

Precision Test Systems supplies many other types of frequency counters and timer-interval counters.  We supply both new and used types.

New Products

For new products we have the U6220 Microwave Universal Timer Counter.  The U6220 has all the features of a universal frequency counter, but with the addition of a 20 GHz option, making the unit into a microwave frequency counter. 

More details of the U6220 are available from http://www.ptsyst.com/Microwave-Frequency-Counter.php

Used Products

We can supply used frequency counters as well.  Please contact sales@ptsyst.com for further details of our current range of used frequency counters.

 

 

00