Home

Site Map    FAQ

Support

Full Brochure List
Distribution Amplifiers
Field Strength Meters
Frequency Counters
Frequency Dividers
Frequency Standards
Function Generator
GPS Amplifier/Splitter
GSM Products
Misc. Products
Multimeter 6.5 digit
Oscillators
Phase Noise Testing
Power Amplifiers
Power Supplies
Protek Products
Redundant Systems
Rubidium Oscillators
Signal Generators
Spectrum Analyzers
Timing Systems
UMTS / GSM Tester
 

FSG960B Portable Signal Generator

 

The FSG960B Field Signal Generator complement Precision Test's FSM960B Field Strength Meter. The FSG960B Field Signal Generator is a synthesized units that will generate a CW signal over the +20 dBm to -20 dBm amplitude range. The frequency is set by the keyboard and the amplitude can be changed in 10 dB steps, also by the keyboard. The FSG960B when used in conjunction with a FSM960B or other field strength meter form a complete measuring system that is ideal in propagation studies of building and local areas.

More details are shown below or click here for a printable pdf brochure. 

 

  • Covers the 890 - 960 MHz frequency range.
  • CW Signal Output from +20 dBm to -20 dBm.
  • Output switchable in 1 dB STEPS
  • Handheld portable units operating on rechargeable batteries
  • Typically five hours use between charges.
  • Compliment Precision Test's FSM range of Field Strength Meters. Ideal for propagation studies of buildings and local areas.

 

Applications

The FSG Field Signal Generator when used in conjunction with the FSM series of field strength meters are ideal for the following applications:

1. Propagation study or mapping of radio systems including analog and digital systems.

2. Measurement of antenna performance of a cellular phone or two way radio.

3. Direction finding using a directional antenna.

 The output of the FSG Generator is a powerful +20 dBm, and can be altered in 10 dB steps from

+20 dBm down to -20 dBm. 

Specifications

Frequency Range

Frequency Accuracy

Generate Level Range

Generate Level Resolution

Generate Level Accuracy

Spurs and Harmonics

Signal Type

Display Type

Battery Life

Charger

Size

Weight

Operating Temperature Range

890 MHz to 960 MHz in 100 kHz steps

± 3 ppm @ 23șC

+20 dBm to -20 dBm

10 dB steps

± 3 dB

-40 dBc or better

CW

Liquid Crystal with back light

Five  hours after full charge

90 - 260 VAC

200 mm x 100 mm x 45 mm

0.62 kg

+10 șC to + 40 șC